Mitsubishi FR-D700 Series Inverter: A Comprehensive Guide
This guide details the Mitsubishi FR-D700 series, offering essential handling information, safety precautions, and instructions for installation, operation, and maintenance of these powerful inverters.
The Mitsubishi FR-D700 series represents a significant advancement in industrial inverter technology, designed to provide precise and efficient control of AC motors across a wide range of applications. These inverters, including models FR-D720 and FR-D740, are renowned for their robust performance, compact design, and user-friendly operation.
This series caters to diverse industrial needs, offering solutions for pumps, fans, compressors, and general-purpose machinery. Mitsubishi Electric’s commitment to innovation is evident in the FR-D700’s advanced features and intuitive programming capabilities. The availability of comprehensive instruction manuals, like the basic manual found on ManualsLib, ensures users have the resources needed for successful implementation and troubleshooting.
Understanding the FR-D700’s capabilities is crucial for optimizing motor control, enhancing energy efficiency, and improving overall system reliability. This guide will delve into the specifics of the series, providing a detailed overview of its features, installation procedures, and operational parameters.
What is the Mitsubishi FR-D700?
The Mitsubishi FR-D700 is a sophisticated variable frequency drive (VFD) meticulously engineered to govern the speed and torque of AC induction motors. Functioning as a power inverter, it transforms incoming AC power into a variable-frequency output, enabling precise motor control. Available in various models – FR-D720 and FR-D740 – it addresses a broad spectrum of industrial automation requirements.

As detailed in available instruction manuals from sources like the Internet Archive and ManualsLib, the FR-D700 isn’t merely a motor starter; it’s a comprehensive motor management system. It optimizes performance, reduces energy consumption, and extends motor lifespan.
The series is designed for ease of use, featuring digital operator functions and straightforward parameter settings. Its robust construction and adherence to stringent safety standards make it a reliable choice for demanding applications. Essentially, the FR-D700 empowers users to tailor motor operation to specific process needs.
Key Features and Benefits
The Mitsubishi FR-D700 series boasts a wealth of features designed to enhance performance and efficiency. Key among these is its advanced motor control, allowing for precise speed and torque regulation, optimizing processes and reducing energy waste. The built-in PID control functionality enables sophisticated closed-loop control applications.
Instruction manuals highlight the FR-D700’s user-friendly interface, facilitated by a digital operator panel and intuitive parameter settings. Its compact design saves valuable panel space, while robust construction ensures reliability in harsh industrial environments.
Furthermore, the series offers comprehensive protection functions, safeguarding both the motor and the drive itself. Benefits include reduced operating costs, improved process control, extended equipment life, and simplified maintenance. The FR-D700 truly delivers a powerful and versatile solution for a wide range of applications.
FR-D700 Model Variations (FR-D720, FR-D740)
The Mitsubishi FR-D700 series encompasses several models, notably the FR-D720 and FR-D740, each tailored to specific application requirements. The FR-D720, available in ratings from 0.1kW to 7.5kW, is a general-purpose inverter suitable for a broad spectrum of motor control tasks. It provides robust performance and essential features for typical industrial applications.
Conversely, the FR-D740, ranging from 0.4kW to 7.5kW, offers enhanced functionality and performance characteristics. Manuals indicate it’s designed for more demanding applications requiring advanced control and communication capabilities.
The FR-D720S is also available, covering 0.1kW to 2.2kW, offering a streamlined and cost-effective solution. Selecting the appropriate model depends on factors like motor size, application complexity, and desired level of control. Careful consideration of these factors ensures optimal system performance and efficiency.

Installation and Wiring
Proper installation and wiring, guided by the instruction manual, are crucial for safe and reliable operation of the Mitsubishi FR-D700 series inverter.
Unpacking and Inspection
Upon receiving your Mitsubishi FR-D700 inverter, carefully inspect the packaging for any signs of damage incurred during shipping. Any visible damage should be immediately reported to the carrier and Mitsubishi Electric. Once the packaging is deemed intact, proceed to carefully unpack the inverter, ensuring all packing materials are removed.
Verify that all components listed in the instruction manual are present. This includes the inverter itself, any optional accessories ordered, and the documentation package – encompassing the instruction manual (basic and detailed), parameter manual, and any supplemental guides.
Thoroughly inspect the inverter for any physical damage, such as cracks, dents, or loose components. Check the cooling fan for free rotation and ensure all terminals are securely fastened. If any damage or missing parts are discovered, do not attempt to install or operate the inverter; contact Mitsubishi Electric support for assistance and guidance.
Mounting the FR-D700 Inverter
Proper mounting is crucial for optimal performance and longevity of your Mitsubishi FR-D700 inverter. Select a clean, dry, and well-ventilated location, free from excessive dust, humidity, and direct sunlight. Ensure sufficient space around the inverter for adequate cooling and easy access for maintenance.
The FR-D700 can be mounted vertically or horizontally, but avoid tilting the unit. Use the provided mounting screws and ensure they are securely tightened to a suitable mounting surface. Avoid mounting the inverter near sources of strong electromagnetic interference, which could affect its operation.
Maintain a minimum clearance of at least 10cm (3.9 inches) around the inverter for ventilation. Confirm the mounting surface can support the weight of the inverter. Proper grounding is essential; ensure a secure connection to the grounding terminal before powering on the unit.
Wiring Diagram Overview
The FR-D700 inverter’s wiring diagram illustrates the connections for power supply, motor, control signals, and protective devices. Carefully review the diagram specific to your model (FR-D720 or FR-D740) before commencing any wiring work. The diagram details the terminals for R, S, T phases, U, V, W motor connections, and braking resistors.
Key components shown include the main circuit, control circuit, and optional components like external braking units. Pay close attention to the recommended wire sizes and types, ensuring they meet the inverter’s current and voltage requirements.
Properly identify the input and output terminals to avoid incorrect connections. The diagram also indicates the grounding points, crucial for safety and preventing electrical noise. Always disconnect power before making or changing any wiring connections. Refer to the detailed wiring sections for specific instructions.
Input and Output Wiring Details
Input wiring for the FR-D700 requires connecting the three-phase power supply (R, S, T) to the designated input terminals. Ensure the supply voltage matches the inverter’s rating. Use appropriately sized cables, considering the current and distance to minimize voltage drop.
Output wiring connects the inverter to the three-phase motor (U, V, W). Employ shielded cables to reduce electromagnetic interference. The braking resistor connection is also crucial for deceleration; connect it to the specified terminals.
Control signal wiring includes connections for the control circuit, such as forward/reverse, start/stop, and speed reference signals. These typically use low-voltage wiring. Always double-check polarity and terminal assignments before energizing the system. Secure all connections tightly to prevent loose wiring and potential faults.

Grounding and Safety Precautions
Proper grounding is paramount for safety and reliable operation of the FR-D700. Connect the inverter’s grounding terminal to a verified earth ground using a dedicated, low-impedance conductor. This protects against electrical shock and minimizes noise interference.
Always disconnect power before performing any wiring or maintenance. High voltages are present even after the inverter is stopped. Never open the inverter enclosure while energized. Qualified personnel should handle installation and troubleshooting.
Observe all relevant electrical codes and safety regulations. Use appropriate personal protective equipment (PPE), including safety glasses and insulated tools. Be cautious of stored energy in capacitors – allow sufficient discharge time before touching any internal components. Regular inspection of wiring and grounding connections is essential for continued safety.

Operation and Programming
The FR-D700 allows precise motor control through parameter settings, digital operator functions, and various speed control methods for optimal performance.
Basic Operation Procedures
Before initiating operation with the Mitsubishi FR-D700, ensure all wiring connections are verified according to the instruction manual, prioritizing safety precautions. Begin by supplying power to the inverter and confirming the initial display shows no fault indications. Utilize the digital operator to navigate to the basic settings, including frequency and voltage parameters.
To start the motor, engage the run command via the operator panel or external terminals. Monitor the motor’s acceleration and deceleration, adjusting parameters as needed for smooth operation. The FR-D700 offers multiple run modes, including forward and reverse, selectable through the control interface.
Always observe the motor’s performance and verify that it operates within its specified limits. Stop the motor using the stop command, and review any displayed messages for potential issues. Refer to the comprehensive manual for detailed guidance on advanced operational features and troubleshooting steps.
Parameter Setting and Configuration
The Mitsubishi FR-D700’s functionality is extensively customizable through its parameter settings, accessed via the digital operator or communication interfaces. Begin by understanding the parameter groups, categorized for ease of navigation – these cover motor data, frequency settings, acceleration/deceleration times, and protection functions.
Accurate motor parameter input (voltage, current, frequency, and speed) is crucial for optimal performance and protection. Configure acceleration and deceleration times to suit the application, preventing mechanical stress. Explore the various frequency setting methods, including V/F control and vector control, to match the load characteristics.
Carefully adjust protection parameters, such as overcurrent and overvoltage limits, to safeguard both the inverter and the connected motor. Save parameter configurations regularly to prevent data loss and facilitate easy restoration. Refer to the detailed manual for a complete explanation of each parameter and its impact on system operation.
Digital Operator Functions

The FR-D700 series inverters feature an integrated digital operator, providing a user-friendly interface for monitoring and control. This keypad allows for direct parameter access, real-time display of operating data (frequency, current, voltage, speed), and fault code diagnostics.
Utilize the operator to initiate and halt operation, adjust frequency references, and switch between preset speeds. The display clearly indicates the inverter’s status, including running, stopping, and fault conditions. Explore the menu structure to access advanced functions like parameter copying and reset options.
The digital operator simplifies troubleshooting by displaying detailed fault messages and providing access to historical data. It also enables quick adjustments to key parameters without requiring external programming tools. Familiarize yourself with the operator’s navigation buttons and menu options for efficient control and monitoring of the inverter.
Speed Control Methods

The Mitsubishi FR-D700 series offers versatile speed control methods to suit diverse application requirements. Vector control provides high-performance torque and speed regulation, ideal for demanding loads and precise positioning. V/F control, a simpler method, is suitable for general-purpose applications like pumps and fans.
Parameter adjustments allow tailoring the speed control characteristics to the specific motor and load. Utilize external speed references – analog inputs (0-10V, 4-20mA) or digital inputs – for remote control. The inverter also supports communication protocols like Modbus for integration with PLCs and other control systems.
Frequency setting capabilities include direct frequency input, preset speeds, and multi-step speed control. Acceleration and deceleration times are adjustable to minimize mechanical stress and ensure smooth operation. Optimize speed control parameters for maximum efficiency and performance in your application.

Troubleshooting and Fault Codes
This section details common FR-D700 fault codes, providing meanings and troubleshooting steps to quickly diagnose and resolve issues for optimal inverter performance.
Common Fault Codes and Their Meanings
Understanding fault codes is crucial for efficient troubleshooting of the Mitsubishi FR-D700 series inverter. These codes signal specific issues within the drive system, allowing for targeted repairs. For example, an OC fault indicates an overcurrent condition, often caused by motor overload or wiring problems. Conversely, an OV fault signifies overvoltage, potentially stemming from supply voltage fluctuations or regenerative braking exceeding capacity.
UF denotes undervoltage, while OH signals overheating, requiring investigation of cooling systems. OL indicates overload, and OP points to overspeed. More complex codes, like those related to encoder feedback or communication errors, require deeper diagnostics. The instruction manual provides a comprehensive list, detailing each code’s precise meaning and recommended corrective actions. Regularly referencing this list will minimize downtime and ensure reliable operation. Ignoring fault codes can lead to further damage and costly repairs.

Troubleshooting Steps for Frequent Issues
When facing common problems with the FR-D700, a systematic approach is key. For motor-not-starting issues, verify power supply, wiring connections, and parameter settings – specifically, motor data. Overcurrent faults (OC) often require checking for short circuits in the motor cable or excessive load. Undervoltage (UF) demands inspection of the input power source and voltage levels.
Overheating (OH) necessitates examining the cooling fan, heatsink cleanliness, and ambient temperature. Communication errors can be resolved by confirming correct communication settings and cable integrity. If the inverter trips repeatedly, analyze the fault history for patterns. Always consult the instruction manual for detailed troubleshooting guidance and specific parameter adjustments. Prioritize safety by disconnecting power before any physical inspection or wiring adjustments. Proper diagnostics minimize downtime and prevent further damage.
Resetting the FR-D700 Inverter
Resetting the FR-D700 can resolve certain operational issues, but understand the implications before proceeding. A “parameter reset” restores factory default settings for parameters, erasing custom configurations – document these beforehand! This is accessed through the digital operator or via software. A “fault reset” clears a triggered fault condition, allowing the inverter to restart, but doesn’t address the underlying cause.
For a complete reset, disconnecting and reconnecting power after a delay can sometimes be necessary. However, this should be a last resort. Always verify the power supply is stable before attempting a restart. Be aware that resetting will remove any stored data, including fault history. Refer to the instruction manual for specific reset procedures and parameter backup/restore options. Incorrect resets can lead to improper operation; proceed cautiously and consult documentation.

Maintenance and Safety
Regular inspections and adherence to safety precautions are crucial for reliable FR-D700 operation and longevity, preventing potential hazards during upkeep.
Regular Maintenance Schedule
To ensure optimal performance and extend the lifespan of your Mitsubishi FR-D700 inverter, a consistent maintenance schedule is paramount. Initially, conduct a visual inspection monthly, checking for dust accumulation, loose wiring connections, and any signs of damage to components. Every six months, carefully clean the cooling fan and heat sink to maintain efficient heat dissipation.
Annually, a more thorough inspection is recommended, including checking the capacitor voltage and insulation resistance. It’s also vital to verify the tightness of all screw terminals and connections. Furthermore, consider professional inspection and testing by a qualified technician every two years to assess the overall health of the inverter and identify potential issues before they escalate. Remember to always disconnect power before performing any maintenance procedures, prioritizing safety at all times. Document all maintenance activities for future reference and troubleshooting.
Safety Precautions During Maintenance
Prioritizing safety is crucial when performing maintenance on the Mitsubishi FR-D700 inverter. Always disconnect the main power supply and wait for at least five minutes to allow capacitors to fully discharge before commencing any work. Never attempt maintenance while the unit is energized. Use insulated tools to prevent accidental short circuits and wear appropriate personal protective equipment (PPE), including safety glasses and insulated gloves.
Avoid touching any internal components, especially those with high voltage potential. Be mindful of hot surfaces, such as the heat sink, which can cause burns. Ensure the work area is well-lit and free from obstructions. If you are not a qualified electrician, do not attempt complex repairs; instead, contact a Mitsubishi-authorized service technician. Always follow the instructions outlined in the FR-D700 instruction manual and adhere to all local electrical safety regulations.